A'PEX SUPER AFC ? Manual de instrucciones Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
48
SUPER
AIRFLOW CONVERTER
SUPER
AIRFLOW CONVERTER
Out
1/2
In
1
Out
Add
Setting the sensor output calculation method (3)
General vehicles using 2 airflow sensors
When the product is used with two airflow sensors and an
ECU with single airflow sensor control.
In
2
Because of a single engine control
unit input, the measured air
volume of the 2 airflow sensors is
added (Add) and its result is output.
In this case, airflow sensor 1 measures an air
volume of 4 and airflow sensor 2 measures an
air volume of 6.
Setting the sensor output calculation method (4)
Skyline GT-R using an airflow sensor
When the product is used with an airflow sensor and an
ECU with twin airflow sensor control.
ECU
ECU
Because of 2 airflow sensors
Measured air volume
4
Measured air volume
6
Input air volume
10
Output air volume
10
Airflow
sensor 1
Airflow
sensor 2
Because of a single airflow sensor
Measured air volume
10
Airflow
sensor
Input air volume
10
Output air volume
5
Output air volume
5
Because of two engine control
unit inputs, the measured air
volume of the airflow sensor is
divided into halves and its result
is output.
In this case, the airflow
sensor measures an air
volume of 10.
Vista de pagina 47